Analox Sub Aspida - Portable Pressure-Compensated O₂ & CO₂ Gas Monitor

The Analox Sub Aspida is a compact, portable dual-gas monitor designed to measure both oxygen (O₂) and carbon dioxide (CO₂) in environments where atmospheric pressure can affect conventional gas-sensor accuracy.

Unlike standard ambient gas monitors, the Sub Aspida incorporates pressure-compensated O₂ and CO₂ sensing. This allows the instrument to account for changes in atmospheric pressure within its rated operating range, helping provide more reliable gas measurements in specialized pressurized and reduced-pressure environments.

The portable platform combines simultaneous O₂ and CO₂ monitoring with datalogging, configurable alarms, a high-visibility OLED display, rechargeable or replaceable AA battery operation, and a rugged IP65-rated enclosure.

Dual-Gas Monitoring Designed for Changing Pressure Environments

  • Simultaneous O₂ + CO₂ monitoring: monitor two critical atmospheric gases from a single handheld instrument
  • Pressure-compensated sensors: engineered to account for atmospheric pressure changes within the instrument's rated operating range
  • Portable operation: compact battery-powered design for continuous monitoring or spot checks
  • Multiple alarm modes: audio, visual, vibration, TWA, fault, and man-down alerts
  • Integrated datalogging: records readings every 30 seconds for at least 7 days of continuous use

Key Features

O₂

Dual O₂ + CO₂ Monitoring

DUAL GAS

Simultaneously monitors oxygen and carbon dioxide from one compact portable instrument.

  • Electrochemical oxygen sensor
  • Analox infrared MIR carbon dioxide sensor
  • Continuous monitoring or spot-check capability
  • Designed for atmospheric safety monitoring applications

Pressure-Compensated Sensors

CORE

Designed specifically for environments where changes in atmospheric pressure can influence conventional gas readings.

  • Pressure-compensated O₂ sensing
  • Pressure-compensated CO₂ sensing
  • Rated operating pressure of 700 to 1200 mbara
  • Useful for specialized pressure-variable environments

High-Visibility OLED Display

Clear digital display provides immediate access to atmospheric gas readings and instrument status.

  • Organic Light Emitting Diode display
  • High-visibility readout
  • Displays monitored gas information simultaneously
  • Designed for rapid interpretation in operational environments
!

Multiple Alarm Systems

Multiple alert methods help make abnormal atmospheric conditions difficult to overlook.

  • 95 dB audible alarm at 30 cm
  • Visual LED alarm indicators
  • Vibration alarm
  • Time Weighted Average alarm
  • Man-down alarm functionality

Integrated Datalogging

Automatically records measurements for later review and documentation.

  • One data log approximately every 30 seconds
  • At least 7 days of continuous-use logging capacity
  • Supports monitoring history and operational review
  • PC configuration software support available from Analox

Portable Battery Operation

Designed to remain useful even where fixed electrical power is unavailable.

  • 2 × NiMH 2100 mAh AA rechargeable batteries
  • Suitable AA-type batteries may also be used
  • Approximately 12-hour nominal operating time
  • Approximately 4.5-hour charge time from flat

Compact & Wearable

Small enough for personal monitoring while remaining capable of fixed-position use.

  • Approximately 5 × 1.7 × 3.5 inches
  • Approximately 11.8 to 12.3 oz depending on configuration
  • Belt-clip configurations available
  • Wall or panel mounting configurations available

User-Maintainable Platform

Designed to simplify routine maintenance and sensor management.

  • O₂ sensor can be calibrated in fresh air
  • CO₂ sensor typically requires calibration every 12 months
  • Maintenance reminders built into the system
  • Replaceable sensor architecture

Why Pressure Compensation Matters

Gas sensors calibrated at normal atmospheric pressure may behave differently when ambient pressure changes. In pressure-variable environments, the relationship between gas concentration, partial pressure, and the sensor response becomes especially important.

The Sub Aspida was developed specifically for these applications. Its pressure-compensated sensing architecture helps account for changes in surrounding atmospheric pressure so that O₂ and CO₂ measurements remain meaningful throughout the unit's specified operating range.

O₂

Oxygen Monitoring

Oxygen concentration can become critical in both oxygen-enriched and oxygen-deficient environments.

  • Monitors oxygen using an electrochemical sensor
  • Supports oxygen-enrichment monitoring
  • Supports oxygen-deficiency monitoring
  • Pressure compensation helps account for changing conditions
CO₂

Carbon Dioxide Monitoring

CO₂ accumulation can occur in enclosed or poorly ventilated environments and may not be apparent without instrumentation.

  • Analox infrared MIR sensing technology
  • Measures CO₂ partial pressure
  • Continuous atmospheric monitoring capability
  • Multiple alarm modes available
Important pressure specification: The manufacturer's published operating-pressure range for the Sub Aspida is 700 to 1200 mbara. Pressure compensation does not mean the instrument may be operated beyond its specified pressure range. Always confirm the operating pressure of the intended environment before use.

Applications & Use Cases

Pressurized environments
Monitoring O₂ and CO₂ where atmospheric pressure varies within the Sub Aspida's rated 700 to 1200 mbara operating range.
Submarine environments
Personal or secondary atmospheric monitoring in applicable submarine, rescue-vehicle, and underwater-system environments.
Aircraft & altitude
Pressure-compensated atmospheric monitoring in applicable aircraft and reduced-pressure environments.
Confined spaces
Portable O₂ and CO₂ monitoring in applicable enclosed or confined-space environments.
Dry-ice logistics
CO₂ monitoring for applicable transport, storage, and logistics environments where dry ice may produce elevated carbon dioxide.
Secondary monitoring
Compact portable configuration makes the Sub Aspida useful as an independent or secondary atmospheric monitoring instrument.
Hyperbaric-use note: Although manufacturer literature has referenced hyperbaric-related applications, this Sub Aspida model carries a published operating pressure specification of 700 to 1200 mbara. It should not be assumed suitable for operation at 1.5 ATA, 2.0 ATA, or other pressures above the manufacturer's stated limit.

System Specifications

Product
Analox Sub Aspida
Monitor type
Portable dual-gas O₂ and CO₂ atmospheric monitor
Operating temperature
0°C to +50°C / 32°F to 122°F
Operating pressure
700 to 1200 mbara
Humidity range
0 to 99% RH
Display
High-visibility OLED display
Alarm horn
95 dB at 30 cm
LED indicators
Green: OK
Amber: Fault
Red: Alarm
Internal data log
One log every 30 seconds for at least 7 days of continuous use
Battery type
2 × NiMH 2100 mAh AA batteries or suitable AA-type batteries
Battery operating time
Approximately 12 hours under normal passive monitoring conditions
Battery lifespan
Approximately 2 years
Battery charge time
Approximately 4.5 hours from flat
Charging power supply
9 V DC, 0.55 A
DC connection
5.5 × 12.0 × 2.1 mm center positive
IP rating
IP65
Dimensions
127 × 44 × 90 mm
Approx. 5 × 1.7 × 3.5 in.
Typical weight
Approx. 335 g / 11.8 oz

CO₂ Sensor Specifications

Sensor type
Analox infrared MIR
Measured gas
Carbon dioxide (CO₂)
Sensor range
0.01 to 50.0 mbar ppCO₂
Equivalent concentration
0.01 to 5% CO₂ at 1000 mbara
Accuracy
±(1% of full scale + 2% of reading) at standard temperature and pressure
Response time
T90 <60 seconds
Expected sensor life
Approximately 5 years
Calibration interval
Manufacturer guidance indicates CO₂ calibration approximately every 12 months

O₂ Sensor Specifications

Sensor type
Electrochemical
Measured gas
Oxygen (O₂)
Sensor range
0.1 to 2000.0 mbar ppO₂
Equivalent concentration
0.1 to 100% O₂ at 1000 mbara
Accuracy
±1% of full scale at standard temperature and pressure
Response time
T90 <30 seconds
Expected sensor life
Approximately 1 year
Calibration
O₂ sensor may be calibrated using fresh air. Manufacturer guidance recommends calibration while operating on battery power.

Alarm & Safety Functions

Audible alarm
95 dB alarm horn measured at 30 cm
Visual alarm
Dedicated green, amber, and red LED status indicators
Vibration alarm
Tactile alert provides an additional notification method
TWA alarm
Time Weighted Average alarm functionality
Man-down alarm
Integrated man-down functionality provides an additional personnel-safety alert
Fault indication
Amber LED indicates instrument or system fault conditions

Datalogging & Monitoring

Monitoring modes
Continuous atmospheric monitoring or individual spot checking
Logging interval
Approximately one recorded measurement every 30 seconds
Logging capacity
At least 7 days of continuous-use data
Configuration
Compatible with Analox Sub Aspida configuration software
Personal monitoring
Compact design supports belt-worn personal monitoring
Fixed monitoring
Selected configurations can be clipped or mounted to a panel or wall location

Battery & Power

Battery configuration
2 × NiMH 2100 mAh AA batteries
Alternate batteries
Suitable AA-type batteries may be used according to manufacturer guidance
Typical operating time
Approximately 12 hours under normal passive-monitoring conditions
Charge time
Approximately 4.5 hours from fully depleted
Battery lifespan
Approximately 2 years
Charger
9 V DC, 0.55 A power supply

Calibration & Maintenance

O₂ calibration
Oxygen sensor can be calibrated using fresh air, reducing the need for a dedicated oxygen calibration cylinder for routine air calibration
CO₂ calibration
Manufacturer guidance specifies approximately annual CO₂ calibration
CO₂ sensor life
Approximately 5 years
O₂ sensor life
Approximately 1 year expected
Maintenance reminders
Integrated maintenance reminders help support scheduled instrument servicing
Serviceability
Designed as a user-maintainable monitoring platform with replaceable sensing components

Warranty

Electronics warranty
2 years
Consumable sensors
Sensor cells and other consumable components may have separate expected service lives and warranty terms
Product support
MedEq Fitness provides product guidance and coordinates applicable manufacturer support

Ordering & Configuration

The Sub Aspida has been produced in several sensor-range and mounting configurations. Final configuration should be selected according to the intended monitoring environment and required measurement range.

CO₂ measurement
Configurations are available for CO₂ concentration or CO₂ partial-pressure monitoring
O₂ measurement
Configurations are available for oxygen concentration or oxygen partial-pressure monitoring
Personal mounting
Belt-clip configuration available for portable personal monitoring
Fixed mounting
Wall or panel-mountable configurations may be available

Need help selecting the correct configuration? Contact MedEq Fitness before ordering and we can help match the sensor range and mounting configuration to the intended application.

Important Use & Pressure Information

Rated pressure range: 700 to 1200 mbara.

The Sub Aspida is a pressure-compensated gas monitor, but pressure compensation should not be confused with unlimited pressure compatibility. The instrument should only be operated within the pressure, temperature, humidity, gas-range, and environmental limits specified by the manufacturer.

In particular, the published 1200 mbara upper operating limit is below the absolute pressure found inside typical 1.3 ATA, 1.5 ATA, and 2.0 ATA hyperbaric chambers. Do not use this model above its published operating-pressure specification.

Users are responsible for determining whether the instrument, sensor configuration, alarm settings, and environmental ratings are appropriate for their specific application. Follow all Analox operating, calibration, maintenance, and safety instructions.

Why Buy Through MedEq Fitness?

Application-Focused Selection

We help evaluate the monitor against the environment in which you plan to use it.

  • Pressure-range review
  • Sensor-range selection
  • O₂ and CO₂ monitoring considerations
  • Mounting and operational requirements

Hyperbaric Equipment Expertise

MedEq understands that atmospheric monitoring requirements change substantially when pressure changes.

  • Experience with hyperbaric equipment environments
  • Attention to absolute-pressure ratings
  • Gas-monitoring equipment selection guidance
  • Support for professional and wellness facilities

MedEq Fitness - Physician-founded, veteran-owned, physician-guided wellness and recovery equipment.

Exclusive Lifestyle Collective Partner

MedEq Fitness × Erewhon

Physician-led wellness and recovery technology curated for elevated lifestyle environments.

Learn More