{"product_id":"analox-sub-aspida-o2-co2-gas-monitor","title":"Analox Sub Aspida Portable Pressure-Compensated O2 \u0026 CO2 Gas Monitor","description":"\u003cstyle\u003e\n\/* MedEq Product Page Styling - Sub Aspida\n   Uses established medeq-hc-cy12 PDP architecture\n*\/\n\n.product-description.medeq-hc-cy12 {\n  max-width: 900px;\n  margin: 0 auto;\n  color: #1f2933;\n  line-height: 1.65;\n}\n\n.product-description.medeq-hc-cy12 h2 {\n  color: #063456;\n  margin: 0 0 14px;\n  line-height: 1.2;\n}\n\n.product-description.medeq-hc-cy12 h3,\n.product-description.medeq-hc-cy12 h4 {\n  line-height: 1.3;\n}\n\n.product-description.medeq-hc-cy12 a {\n  color: #063456;\n  text-decoration: underline;\n  text-underline-offset: 3px;\n}\n\n\/* Highlight Banner *\/\n.product-description.medeq-hc-cy12 .hc-whats-new-banner {\n  background: #063456;\n  color: #ffffff;\n  border-radius: 16px;\n  padding: 22px 24px;\n  margin: 28px 0;\n  box-shadow: 0 10px 24px rgba(6, 52, 86, 0.16);\n}\n\n.product-description.medeq-hc-cy12 .hc-whats-new-banner h3 {\n  color: #ffffff;\n  margin: 0 0 10px;\n  line-height: 1.25;\n}\n\n.product-description.medeq-hc-cy12 .hc-whats-new-banner ul {\n  margin: 0;\n  padding-left: 20px;\n}\n\n\/* Accordion *\/\n.product-description.medeq-hc-cy12 .hc-accordion-item {\n  border: 1px solid rgba(6, 52, 86, 0.18);\n  border-radius: 14px;\n  margin: 18px 0;\n  overflow: hidden;\n  background: #ffffff;\n  box-shadow: 0 6px 18px rgba(6, 52, 86, 0.08);\n}\n\n.product-description.medeq-hc-cy12 .hc-accordion-header {\n  background: #063456;\n  color: #ffffff;\n  margin: 0;\n  padding: 16px 20px;\n  cursor: pointer;\n  font-size: 1.08rem;\n  line-height: 1.25;\n  position: relative;\n}\n\n.product-description.medeq-hc-cy12 .hc-accordion-header::after {\n  content: \"▾\";\n  position: absolute;\n  right: 18px;\n  top: 50%;\n  transform: translateY(-50%);\n  font-size: 0.95rem;\n}\n\n.product-description.medeq-hc-cy12\n  .hc-accordion-item.active\n  .hc-accordion-header::after,\n.product-description.medeq-hc-cy12\n  .hc-accordion-item.open\n  .hc-accordion-header::after {\n  content: \"▴\";\n}\n\n.product-description.medeq-hc-cy12 .hc-accordion-content {\n  padding: 20px;\n}\n\n\/* Feature Grid *\/\n.product-description.medeq-hc-cy12 .hc-feature-grid {\n  display: grid;\n  grid-template-columns: repeat(2, minmax(0, 1fr));\n  gap: 16px;\n}\n\n.product-description.medeq-hc-cy12 .hc-feature-card,\n.product-description.medeq-hc-cy12 .hc-spec-card {\n  border: 1px solid rgba(6, 52, 86, 0.16);\n  border-radius: 14px;\n  background: #fbfcfd;\n  padding: 16px;\n}\n\n.product-description.medeq-hc-cy12 .hc-feature-card.hc-new-feature {\n  border-color: rgba(201, 169, 110, 0.55);\n  background: #fffdf8;\n}\n\n.product-description.medeq-hc-cy12 .feature-header {\n  display: flex;\n  align-items: center;\n  gap: 10px;\n  margin-bottom: 8px;\n}\n\n.product-description.medeq-hc-cy12 .feature-icon {\n  font-size: 1.35rem;\n  line-height: 1;\n}\n\n.product-description.medeq-hc-cy12 .feature-header h4 {\n  color: #063456;\n  margin: 0;\n  font-size: 1rem;\n  line-height: 1.25;\n  flex: 1;\n}\n\n.product-description.medeq-hc-cy12 .new-badge {\n  display: inline-block;\n  background: #c9a96e;\n  color: #063456;\n  border-radius: 999px;\n  padding: 4px 8px;\n  font-size: 0.68rem;\n  font-weight: 700;\n  letter-spacing: 0.04em;\n  white-space: nowrap;\n}\n\n.product-description.medeq-hc-cy12 .feature-summary {\n  margin: 8px 0 10px;\n}\n\n.product-description.medeq-hc-cy12 .feature-details ul {\n  margin: 0 0 10px;\n  padding-left: 18px;\n}\n\n.product-description.medeq-hc-cy12 .hc-feature-more-toggle {\n  appearance: none;\n  border: 1px solid rgba(6, 52, 86, 0.3);\n  background: #ffffff;\n  color: #063456;\n  border-radius: 999px;\n  padding: 7px 12px;\n  font-weight: 700;\n  cursor: pointer;\n}\n\n\/* Specification Grid *\/\n.product-description.medeq-hc-cy12 .hc-spec-grid {\n  display: grid;\n  grid-template-columns: repeat(2, minmax(0, 1fr));\n  gap: 14px;\n}\n\n.product-description.medeq-hc-cy12 .hc-spec-grid::before {\n  content: attr(data-title);\n  grid-column: 1 \/ -1;\n  color: #063456;\n  font-weight: 700;\n  font-size: 1.05rem;\n  margin-bottom: 2px;\n}\n\n.product-description.medeq-hc-cy12 .hc-spec-label {\n  color: #063456;\n  font-weight: 700;\n  font-size: 0.84rem;\n  text-transform: uppercase;\n  letter-spacing: 0.04em;\n  margin-bottom: 6px;\n}\n\n.product-description.medeq-hc-cy12 .hc-spec-value {\n  color: #1f2933;\n}\n\n\/* Important Specification Notice *\/\n.product-description.medeq-hc-cy12 .subaspida-pressure-note {\n  border: 1px solid rgba(201, 169, 110, 0.65);\n  background: #fffdf8;\n  border-radius: 14px;\n  padding: 18px 20px;\n  margin: 18px 0 4px;\n}\n\n.product-description.medeq-hc-cy12 .subaspida-pressure-note strong {\n  color: #063456;\n}\n\n\/* Small Section Heading *\/\n.product-description.medeq-hc-cy12 .subaspida-subheading {\n  color: #063456;\n  margin: 24px 0 12px;\n  font-size: 1.05rem;\n}\n\n\/* Mobile *\/\n@media (max-width: 720px) {\n  .product-description.medeq-hc-cy12 .hc-feature-grid,\n  .product-description.medeq-hc-cy12 .hc-spec-grid {\n    grid-template-columns: 1fr;\n  }\n\n  .product-description.medeq-hc-cy12 .hc-accordion-header {\n    padding-right: 44px;\n  }\n}\n\u003c\/style\u003e\n\n\n\u003cdiv class=\"product-description medeq-hc-cy12 medeq-subaspida\"\u003e\n\n  \u003ch2\u003eAnalox Sub Aspida - Portable Pressure-Compensated O₂ \u0026amp; CO₂ Gas Monitor\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eAnalox Sub Aspida\u003c\/strong\u003e is a compact, portable dual-gas\n    monitor designed to measure both \u003cstrong\u003eoxygen (O₂)\u003c\/strong\u003e and\n    \u003cstrong\u003ecarbon dioxide (CO₂)\u003c\/strong\u003e in environments where atmospheric\n    pressure can affect conventional gas-sensor accuracy.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    Unlike standard ambient gas monitors, the Sub Aspida incorporates\n    \u003cstrong\u003epressure-compensated O₂ and CO₂ sensing\u003c\/strong\u003e. This allows the\n    instrument to account for changes in atmospheric pressure within its rated\n    operating range, helping provide more reliable gas measurements in\n    specialized pressurized and reduced-pressure environments.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    The portable platform combines simultaneous O₂ and CO₂ monitoring with\n    datalogging, configurable alarms, a high-visibility OLED display,\n    rechargeable or replaceable AA battery operation, and a rugged\n    \u003cstrong\u003eIP65-rated enclosure\u003c\/strong\u003e.\n  \u003c\/p\u003e\n\n\n  \u003c!-- Highlight Banner --\u003e\n  \u003cdiv class=\"hc-whats-new-banner\"\u003e\n    \u003ch3\u003eDual-Gas Monitoring Designed for Changing Pressure Environments\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n        \u003cstrong\u003eSimultaneous O₂ + CO₂ monitoring:\u003c\/strong\u003e\n        monitor two critical atmospheric gases from a single handheld instrument\n      \u003c\/li\u003e\n      \u003cli\u003e\n        \u003cstrong\u003ePressure-compensated sensors:\u003c\/strong\u003e\n        engineered to account for atmospheric pressure changes within the\n        instrument's rated operating range\n      \u003c\/li\u003e\n      \u003cli\u003e\n        \u003cstrong\u003ePortable operation:\u003c\/strong\u003e\n        compact battery-powered design for continuous monitoring or spot checks\n      \u003c\/li\u003e\n      \u003cli\u003e\n        \u003cstrong\u003eMultiple alarm modes:\u003c\/strong\u003e\n        audio, visual, vibration, TWA, fault, and man-down alerts\n      \u003c\/li\u003e\n      \u003cli\u003e\n        \u003cstrong\u003eIntegrated datalogging:\u003c\/strong\u003e\n        records readings every 30 seconds for at least 7 days of continuous use\n      \u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Key Features Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eKey Features\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n      \u003cdiv class=\"hc-feature-grid\"\u003e\n\n        \u003cdiv class=\"hc-feature-card hc-new-feature\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003eO₂\u003c\/span\u003e\n            \u003ch4\u003eDual O₂ + CO₂ Monitoring\u003c\/h4\u003e\n            \u003cspan class=\"new-badge\"\u003eDUAL GAS\u003c\/span\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Simultaneously monitors oxygen and carbon dioxide from one\n            compact portable instrument.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eElectrochemical oxygen sensor\u003c\/li\u003e\n              \u003cli\u003eAnalox infrared MIR carbon dioxide sensor\u003c\/li\u003e\n              \u003cli\u003eContinuous monitoring or spot-check capability\u003c\/li\u003e\n              \u003cli\u003eDesigned for atmospheric safety monitoring applications\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card hc-new-feature\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e◉\u003c\/span\u003e\n            \u003ch4\u003ePressure-Compensated Sensors\u003c\/h4\u003e\n            \u003cspan class=\"new-badge\"\u003eCORE\u003c\/span\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Designed specifically for environments where changes in\n            atmospheric pressure can influence conventional gas readings.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003ePressure-compensated O₂ sensing\u003c\/li\u003e\n              \u003cli\u003ePressure-compensated CO₂ sensing\u003c\/li\u003e\n              \u003cli\u003eRated operating pressure of 700 to 1200 mbara\u003c\/li\u003e\n              \u003cli\u003eUseful for specialized pressure-variable environments\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e▣\u003c\/span\u003e\n            \u003ch4\u003eHigh-Visibility OLED Display\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Clear digital display provides immediate access to atmospheric\n            gas readings and instrument status.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eOrganic Light Emitting Diode display\u003c\/li\u003e\n              \u003cli\u003eHigh-visibility readout\u003c\/li\u003e\n              \u003cli\u003eDisplays monitored gas information simultaneously\u003c\/li\u003e\n              \u003cli\u003eDesigned for rapid interpretation in operational environments\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e!\u003c\/span\u003e\n            \u003ch4\u003eMultiple Alarm Systems\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Multiple alert methods help make abnormal atmospheric conditions\n            difficult to overlook.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003e95 dB audible alarm at 30 cm\u003c\/li\u003e\n              \u003cli\u003eVisual LED alarm indicators\u003c\/li\u003e\n              \u003cli\u003eVibration alarm\u003c\/li\u003e\n              \u003cli\u003eTime Weighted Average alarm\u003c\/li\u003e\n              \u003cli\u003eMan-down alarm functionality\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e↻\u003c\/span\u003e\n            \u003ch4\u003eIntegrated Datalogging\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Automatically records measurements for later review and\n            documentation.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eOne data log approximately every 30 seconds\u003c\/li\u003e\n              \u003cli\u003eAt least 7 days of continuous-use logging capacity\u003c\/li\u003e\n              \u003cli\u003eSupports monitoring history and operational review\u003c\/li\u003e\n              \u003cli\u003ePC configuration software support available from Analox\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e⚡\u003c\/span\u003e\n            \u003ch4\u003ePortable Battery Operation\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Designed to remain useful even where fixed electrical power is\n            unavailable.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003e2 × NiMH 2100 mAh AA rechargeable batteries\u003c\/li\u003e\n              \u003cli\u003eSuitable AA-type batteries may also be used\u003c\/li\u003e\n              \u003cli\u003eApproximately 12-hour nominal operating time\u003c\/li\u003e\n              \u003cli\u003eApproximately 4.5-hour charge time from flat\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e◆\u003c\/span\u003e\n            \u003ch4\u003eCompact \u0026amp; Wearable\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Small enough for personal monitoring while remaining capable of\n            fixed-position use.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eApproximately 5 × 1.7 × 3.5 inches\u003c\/li\u003e\n              \u003cli\u003eApproximately 11.8 to 12.3 oz depending on configuration\u003c\/li\u003e\n              \u003cli\u003eBelt-clip configurations available\u003c\/li\u003e\n              \u003cli\u003eWall or panel mounting configurations available\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e✓\u003c\/span\u003e\n            \u003ch4\u003eUser-Maintainable Platform\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Designed to simplify routine maintenance and sensor management.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eO₂ sensor can be calibrated in fresh air\u003c\/li\u003e\n              \u003cli\u003eCO₂ sensor typically requires calibration every 12 months\u003c\/li\u003e\n              \u003cli\u003eMaintenance reminders built into the system\u003c\/li\u003e\n              \u003cli\u003eReplaceable sensor architecture\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Why Pressure Compensation Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eWhy Pressure Compensation Matters\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cp\u003e\n        Gas sensors calibrated at normal atmospheric pressure may behave\n        differently when ambient pressure changes. In pressure-variable\n        environments, the relationship between gas concentration,\n        partial pressure, and the sensor response becomes especially important.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        The Sub Aspida was developed specifically for these applications.\n        Its pressure-compensated sensing architecture helps account for\n        changes in surrounding atmospheric pressure so that O₂ and CO₂\n        measurements remain meaningful throughout the unit's specified\n        operating range.\n      \u003c\/p\u003e\n\n      \u003cdiv class=\"hc-feature-grid\"\u003e\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003eO₂\u003c\/span\u003e\n            \u003ch4\u003eOxygen Monitoring\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Oxygen concentration can become critical in both oxygen-enriched\n            and oxygen-deficient environments.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eMonitors oxygen using an electrochemical sensor\u003c\/li\u003e\n              \u003cli\u003eSupports oxygen-enrichment monitoring\u003c\/li\u003e\n              \u003cli\u003eSupports oxygen-deficiency monitoring\u003c\/li\u003e\n              \u003cli\u003ePressure compensation helps account for changing conditions\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003eCO₂\u003c\/span\u003e\n            \u003ch4\u003eCarbon Dioxide Monitoring\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            CO₂ accumulation can occur in enclosed or poorly ventilated\n            environments and may not be apparent without instrumentation.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eAnalox infrared MIR sensing technology\u003c\/li\u003e\n              \u003cli\u003eMeasures CO₂ partial pressure\u003c\/li\u003e\n              \u003cli\u003eContinuous atmospheric monitoring capability\u003c\/li\u003e\n              \u003cli\u003eMultiple alarm modes available\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"subaspida-pressure-note\"\u003e\n        \u003cstrong\u003eImportant pressure specification:\u003c\/strong\u003e\n        The manufacturer's published operating-pressure range for the\n        Sub Aspida is \u003cstrong\u003e700 to 1200 mbara\u003c\/strong\u003e. Pressure compensation\n        does not mean the instrument may be operated beyond its specified\n        pressure range. Always confirm the operating pressure of the intended\n        environment before use.\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Applications Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eApplications \u0026amp; Use Cases\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Designed for Specialized Atmospheric Monitoring\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003ePressurized environments\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Monitoring O₂ and CO₂ where atmospheric pressure varies within\n            the Sub Aspida's rated 700 to 1200 mbara operating range.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSubmarine environments\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Personal or secondary atmospheric monitoring in applicable\n            submarine, rescue-vehicle, and underwater-system environments.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eAircraft \u0026amp; altitude\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Pressure-compensated atmospheric monitoring in applicable\n            aircraft and reduced-pressure environments.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eConfined spaces\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Portable O₂ and CO₂ monitoring in applicable enclosed or\n            confined-space environments.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eDry-ice logistics\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            CO₂ monitoring for applicable transport, storage, and logistics\n            environments where dry ice may produce elevated carbon dioxide.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSecondary monitoring\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Compact portable configuration makes the Sub Aspida useful as\n            an independent or secondary atmospheric monitoring instrument.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"subaspida-pressure-note\"\u003e\n        \u003cstrong\u003eHyperbaric-use note:\u003c\/strong\u003e\n        Although manufacturer literature has referenced hyperbaric-related\n        applications, this Sub Aspida model carries a published operating\n        pressure specification of \u003cstrong\u003e700 to 1200 mbara\u003c\/strong\u003e.\n        It should not be assumed suitable for operation at 1.5 ATA,\n        2.0 ATA, or other pressures above the manufacturer's stated limit.\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- System Specifications Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eSystem Specifications\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Sub Aspida System Specifications\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eProduct\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analox Sub Aspida\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMonitor type\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Portable dual-gas O₂ and CO₂ atmospheric monitor\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eOperating temperature\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            0°C to +50°C \/ 32°F to 122°F\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eOperating pressure\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e700 to 1200 mbara\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eHumidity range\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            0 to 99% RH\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eDisplay\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            High-visibility OLED display\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eAlarm horn\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            95 dB at 30 cm\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eLED indicators\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Green: OK\u003cbr\u003e\n            Amber: Fault\u003cbr\u003e\n            Red: Alarm\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eInternal data log\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            One log every 30 seconds for at least 7 days of continuous use\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery type\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            2 × NiMH 2100 mAh AA batteries or suitable AA-type batteries\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery operating time\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 12 hours under normal passive monitoring conditions\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery lifespan\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 2 years\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery charge time\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 4.5 hours from flat\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCharging power supply\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            9 V DC, 0.55 A\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eDC connection\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            5.5 × 12.0 × 2.1 mm center positive\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eIP rating\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003eIP65\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eDimensions\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            127 × 44 × 90 mm\u003cbr\u003e\n            Approx. 5 × 1.7 × 3.5 in.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eTypical weight\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. 335 g \/ 11.8 oz\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- CO2 Sensor Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eCO₂ Sensor Specifications\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Carbon Dioxide Sensor\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor type\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analox infrared MIR\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMeasured gas\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Carbon dioxide (CO₂)\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor range\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e0.01 to 50.0 mbar ppCO₂\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eEquivalent concentration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            0.01 to 5% CO₂ at 1000 mbara\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eAccuracy\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            ±(1% of full scale + 2% of reading) at standard temperature\n            and pressure\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eResponse time\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            T90 \u0026lt;60 seconds\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eExpected sensor life\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 5 years\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCalibration interval\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Manufacturer guidance indicates CO₂ calibration approximately\n            every 12 months\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- O2 Sensor Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eO₂ Sensor Specifications\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Oxygen Sensor\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor type\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Electrochemical\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMeasured gas\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Oxygen (O₂)\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor range\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e0.1 to 2000.0 mbar ppO₂\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eEquivalent concentration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            0.1 to 100% O₂ at 1000 mbara\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eAccuracy\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            ±1% of full scale at standard temperature and pressure\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eResponse time\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            T90 \u0026lt;30 seconds\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eExpected sensor life\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 1 year\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCalibration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            O₂ sensor may be calibrated using fresh air. Manufacturer\n            guidance recommends calibration while operating on battery power.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Alarms Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eAlarm \u0026amp; Safety Functions\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Integrated Alert Systems\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eAudible alarm\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            95 dB alarm horn measured at 30 cm\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eVisual alarm\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Dedicated green, amber, and red LED status indicators\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eVibration alarm\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Tactile alert provides an additional notification method\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eTWA alarm\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Time Weighted Average alarm functionality\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMan-down alarm\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Integrated man-down functionality provides an additional\n            personnel-safety alert\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eFault indication\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Amber LED indicates instrument or system fault conditions\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Datalogging Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eDatalogging \u0026amp; Monitoring\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Monitoring Capabilities\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMonitoring modes\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Continuous atmospheric monitoring or individual spot checking\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eLogging interval\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately one recorded measurement every 30 seconds\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eLogging capacity\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            At least 7 days of continuous-use data\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eConfiguration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Compatible with Analox Sub Aspida configuration software\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003ePersonal monitoring\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Compact design supports belt-worn personal monitoring\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eFixed monitoring\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Selected configurations can be clipped or mounted to a panel\n            or wall location\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Power Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eBattery \u0026amp; Power\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Portable Power System\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery configuration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            2 × NiMH 2100 mAh AA batteries\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eAlternate batteries\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Suitable AA-type batteries may be used according to\n            manufacturer guidance\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eTypical operating time\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 12 hours under normal passive-monitoring conditions\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCharge time\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 4.5 hours from fully depleted\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery lifespan\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 2 years\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCharger\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            9 V DC, 0.55 A power supply\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Maintenance Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eCalibration \u0026amp; Maintenance\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Routine Instrument Care\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eO₂ calibration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Oxygen sensor can be calibrated using fresh air, reducing the\n            need for a dedicated oxygen calibration cylinder for routine\n            air calibration\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCO₂ calibration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Manufacturer guidance specifies approximately annual CO₂\n            calibration\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCO₂ sensor life\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 5 years\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eO₂ sensor life\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approximately 1 year expected\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMaintenance reminders\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Integrated maintenance reminders help support scheduled\n            instrument servicing\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eServiceability\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Designed as a user-maintainable monitoring platform with\n            replaceable sensing components\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Warranty Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eWarranty\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Manufacturer Warranty\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eElectronics warranty\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e2 years\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eConsumable sensors\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Sensor cells and other consumable components may have separate\n            expected service lives and warranty terms\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eProduct support\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            MedEq Fitness provides product guidance and coordinates\n            applicable manufacturer support\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Ordering Accordion --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eOrdering \u0026amp; Configuration\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cp\u003e\n        The Sub Aspida has been produced in several sensor-range and mounting\n        configurations. Final configuration should be selected according to\n        the intended monitoring environment and required measurement range.\n      \u003c\/p\u003e\n\n      \u003cdiv data-title=\"Available Configuration Considerations\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCO₂ measurement\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Configurations are available for CO₂ concentration or CO₂\n            partial-pressure monitoring\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eO₂ measurement\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Configurations are available for oxygen concentration or\n            oxygen partial-pressure monitoring\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003ePersonal mounting\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Belt-clip configuration available for portable personal monitoring\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eFixed mounting\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Wall or panel-mountable configurations may be available\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cp style=\"margin-top: 16px;\"\u003e\n        \u003cstrong\u003eNeed help selecting the correct configuration?\u003c\/strong\u003e\n        Contact MedEq Fitness before ordering and we can help match the sensor\n        range and mounting configuration to the intended application.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Important Use Information --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eImportant Use \u0026amp; Pressure Information\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv class=\"subaspida-pressure-note\"\u003e\n        \u003cstrong\u003eRated pressure range: 700 to 1200 mbara.\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\n        The Sub Aspida is a pressure-compensated gas monitor, but pressure\n        compensation should not be confused with unlimited pressure\n        compatibility. The instrument should only be operated within the\n        pressure, temperature, humidity, gas-range, and environmental limits\n        specified by the manufacturer.\n        \u003cbr\u003e\u003cbr\u003e\n\n        In particular, the published 1200 mbara upper operating limit is below\n        the absolute pressure found inside typical 1.3 ATA, 1.5 ATA, and\n        2.0 ATA hyperbaric chambers. Do not use this model above its published\n        operating-pressure specification.\n      \u003c\/div\u003e\n\n      \u003cp style=\"margin-top: 18px;\"\u003e\n        Users are responsible for determining whether the instrument,\n        sensor configuration, alarm settings, and environmental ratings are\n        appropriate for their specific application. Follow all Analox\n        operating, calibration, maintenance, and safety instructions.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- MedEq Support --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eWhy Buy Through MedEq Fitness?\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv class=\"hc-feature-grid\"\u003e\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e✓\u003c\/span\u003e\n            \u003ch4\u003eApplication-Focused Selection\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            We help evaluate the monitor against the environment in which\n            you plan to use it.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003ePressure-range review\u003c\/li\u003e\n              \u003cli\u003eSensor-range selection\u003c\/li\u003e\n              \u003cli\u003eO₂ and CO₂ monitoring considerations\u003c\/li\u003e\n              \u003cli\u003eMounting and operational requirements\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e◎\u003c\/span\u003e\n            \u003ch4\u003eHyperbaric Equipment Expertise\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            MedEq understands that atmospheric monitoring requirements change\n            substantially when pressure changes.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eExperience with hyperbaric equipment environments\u003c\/li\u003e\n              \u003cli\u003eAttention to absolute-pressure ratings\u003c\/li\u003e\n              \u003cli\u003eGas-monitoring equipment selection guidance\u003c\/li\u003e\n              \u003cli\u003eSupport for professional and wellness facilities\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cp style=\"margin-top: 18px;\"\u003e\n        \u003cstrong\u003eMedEq Fitness - Physician-founded, veteran-owned,\n        physician-guided wellness and recovery equipment.\u003c\/strong\u003e\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"MedEq Fitness","offers":[{"title":"Default Title","offer_id":56961326481574,"sku":"HC-O2CO2","price":1995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/5512\/1574\/files\/IMG_7531.jpg?v=1786755475","url":"https:\/\/medeqfitness.com\/products\/analox-sub-aspida-o2-co2-gas-monitor","provider":"MedEq Fitness","version":"1.0","type":"link"}