{"product_id":"analox-hyp-hyperbaric-o2-analyzer","title":"Analox HYP Hyperbaric Portable O2 Partial Pressure Analyzer","description":"\u003cstyle\u003e\n\/* MedEq Product Page Styling - Analox HYP\n   Uses established medeq-hc-cy12 PDP architecture\n*\/\n\n.product-description.medeq-hc-cy12 {\n  max-width: 900px;\n  margin: 0 auto;\n  color: #1f2933;\n  line-height: 1.65;\n}\n\n.product-description.medeq-hc-cy12 h2 {\n  color: #063456;\n  margin: 0 0 14px;\n  line-height: 1.2;\n}\n\n.product-description.medeq-hc-cy12 h3,\n.product-description.medeq-hc-cy12 h4 {\n  line-height: 1.3;\n}\n\n.product-description.medeq-hc-cy12 a {\n  color: #063456;\n  text-decoration: underline;\n  text-underline-offset: 3px;\n}\n\n\/* Highlight Banner *\/\n.product-description.medeq-hc-cy12 .hc-whats-new-banner {\n  background: #063456;\n  color: #ffffff;\n  border-radius: 16px;\n  padding: 22px 24px;\n  margin: 28px 0;\n  box-shadow: 0 10px 24px rgba(6, 52, 86, 0.16);\n}\n\n.product-description.medeq-hc-cy12 .hc-whats-new-banner h3 {\n  color: #ffffff;\n  margin: 0 0 10px;\n  line-height: 1.25;\n}\n\n.product-description.medeq-hc-cy12 .hc-whats-new-banner ul {\n  margin: 0;\n  padding-left: 20px;\n}\n\n\/* Accordion *\/\n.product-description.medeq-hc-cy12 .hc-accordion-item {\n  border: 1px solid rgba(6, 52, 86, 0.18);\n  border-radius: 14px;\n  margin: 18px 0;\n  overflow: hidden;\n  background: #ffffff;\n  box-shadow: 0 6px 18px rgba(6, 52, 86, 0.08);\n}\n\n.product-description.medeq-hc-cy12 .hc-accordion-header {\n  background: #063456;\n  color: #ffffff;\n  margin: 0;\n  padding: 16px 20px;\n  cursor: pointer;\n  font-size: 1.08rem;\n  line-height: 1.25;\n  position: relative;\n}\n\n.product-description.medeq-hc-cy12 .hc-accordion-header::after {\n  content: \"▾\";\n  position: absolute;\n  right: 18px;\n  top: 50%;\n  transform: translateY(-50%);\n  font-size: 0.95rem;\n}\n\n.product-description.medeq-hc-cy12\n  .hc-accordion-item.active\n  .hc-accordion-header::after,\n.product-description.medeq-hc-cy12\n  .hc-accordion-item.open\n  .hc-accordion-header::after {\n  content: \"▴\";\n}\n\n.product-description.medeq-hc-cy12 .hc-accordion-content {\n  padding: 20px;\n}\n\n\/* Feature Grid *\/\n.product-description.medeq-hc-cy12 .hc-feature-grid {\n  display: grid;\n  grid-template-columns: repeat(2, minmax(0, 1fr));\n  gap: 16px;\n}\n\n.product-description.medeq-hc-cy12 .hc-feature-card,\n.product-description.medeq-hc-cy12 .hc-spec-card {\n  border: 1px solid rgba(6, 52, 86, 0.16);\n  border-radius: 14px;\n  background: #fbfcfd;\n  padding: 16px;\n}\n\n.product-description.medeq-hc-cy12 .hc-feature-card.hc-new-feature {\n  border-color: rgba(201, 169, 110, 0.55);\n  background: #fffdf8;\n}\n\n.product-description.medeq-hc-cy12 .feature-header {\n  display: flex;\n  align-items: center;\n  gap: 10px;\n  margin-bottom: 8px;\n}\n\n.product-description.medeq-hc-cy12 .feature-icon {\n  font-size: 1.35rem;\n  line-height: 1;\n}\n\n.product-description.medeq-hc-cy12 .feature-header h4 {\n  color: #063456;\n  margin: 0;\n  font-size: 1rem;\n  line-height: 1.25;\n  flex: 1;\n}\n\n.product-description.medeq-hc-cy12 .new-badge {\n  display: inline-block;\n  background: #c9a96e;\n  color: #063456;\n  border-radius: 999px;\n  padding: 4px 8px;\n  font-size: 0.68rem;\n  font-weight: 700;\n  letter-spacing: 0.04em;\n  white-space: nowrap;\n}\n\n.product-description.medeq-hc-cy12 .feature-summary {\n  margin: 8px 0 10px;\n}\n\n.product-description.medeq-hc-cy12 .feature-details ul {\n  margin: 0 0 10px;\n  padding-left: 18px;\n}\n\n.product-description.medeq-hc-cy12 .hc-feature-more-toggle {\n  appearance: none;\n  border: 1px solid rgba(6, 52, 86, 0.3);\n  background: #ffffff;\n  color: #063456;\n  border-radius: 999px;\n  padding: 7px 12px;\n  font-weight: 700;\n  cursor: pointer;\n}\n\n\/* Specification Grid *\/\n.product-description.medeq-hc-cy12 .hc-spec-grid {\n  display: grid;\n  grid-template-columns: repeat(2, minmax(0, 1fr));\n  gap: 14px;\n}\n\n.product-description.medeq-hc-cy12 .hc-spec-grid::before {\n  content: attr(data-title);\n  grid-column: 1 \/ -1;\n  color: #063456;\n  font-weight: 700;\n  font-size: 1.05rem;\n  margin-bottom: 2px;\n}\n\n.product-description.medeq-hc-cy12 .hc-spec-label {\n  color: #063456;\n  font-weight: 700;\n  font-size: 0.84rem;\n  text-transform: uppercase;\n  letter-spacing: 0.04em;\n  margin-bottom: 6px;\n}\n\n.product-description.medeq-hc-cy12 .hc-spec-value {\n  color: #1f2933;\n}\n\n\/* Gold Technical Note *\/\n.product-description.medeq-hc-cy12 .hyp-tech-note {\n  border: 1px solid rgba(201, 169, 110, 0.65);\n  background: #fffdf8;\n  border-radius: 14px;\n  padding: 18px 20px;\n  margin: 18px 0;\n}\n\n.product-description.medeq-hc-cy12 .hyp-tech-note strong {\n  color: #063456;\n}\n\n\/* Equation *\/\n.product-description.medeq-hc-cy12 .hyp-equation {\n  background: #f4f7f9;\n  border-left: 4px solid #c9a96e;\n  padding: 16px 18px;\n  margin: 18px 0;\n  font-weight: 700;\n  color: #063456;\n}\n\n\/* Mobile *\/\n@media (max-width: 720px) {\n  .product-description.medeq-hc-cy12 .hc-feature-grid,\n  .product-description.medeq-hc-cy12 .hc-spec-grid {\n    grid-template-columns: 1fr;\n  }\n\n  .product-description.medeq-hc-cy12 .hc-accordion-header {\n    padding-right: 44px;\n  }\n}\n\u003c\/style\u003e\n\n\n\u003cdiv class=\"product-description medeq-hc-cy12 medeq-analox-hyp\"\u003e\n\n  \u003ch2\u003eAnalox HYP Hyperbaric Portable O₂ Partial Pressure Analyzer\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eAnalox HYP Hyperbaric Oxygen Analyzer\u003c\/strong\u003e is a compact,\n    portable \u003cstrong\u003ehyperbaric O₂ analyzer\u003c\/strong\u003e designed specifically for\n    monitoring oxygen partial pressure inside hyperbaric chambers and other\n    pressurized environments. As a true \u003cstrong\u003ehyperbaric chamber oxygen analyzer\u003c\/strong\u003e,\n    the HYP measures \u003cstrong\u003eppO₂ directly\u003c\/strong\u003e rather than relying solely\n    on oxygen percentage.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    With an operating pressure range of \u003cstrong\u003e0.8 to 60 bar absolute\u003c\/strong\u003e,\n    the HYP functions as a highly capable \u003cstrong\u003epressure-rated oxygen analyzer\u003c\/strong\u003e\n    for hyperbaric chambers, diving bells, hyperbaric lifeboats, submarines,\n    and other pressure-variable environments.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    This \u003cstrong\u003eportable oxygen analyzer\u003c\/strong\u003e measures oxygen partial\n    pressure from \u003cstrong\u003e0 to 2.0 bar ppO₂\u003c\/strong\u003e, making it well suited for\n    facilities that require an independent \u003cstrong\u003eoxygen partial pressure analyzer\u003c\/strong\u003e\n    or \u003cstrong\u003eppO₂ analyzer\u003c\/strong\u003e for chamber atmosphere monitoring.\n    Its compact size, long battery life, and broad pressure rating also make\n    it a practical \u003cstrong\u003ehyperbaric oxygen monitor\u003c\/strong\u003e for professional\n    and specialized chamber environments.\n  \u003c\/p\u003e\n\n\n  \u003c!-- Highlight Banner --\u003e\n  \u003cdiv class=\"hc-whats-new-banner\"\u003e\n    \u003ch3\u003ePurpose-Built Hyperbaric Oxygen Analyzer for Chamber Monitoring\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n        \u003cstrong\u003eHyperbaric pressure rated:\u003c\/strong\u003e\n        designed for operation from 0.8 to 60 bar absolute\n      \u003c\/li\u003e\n      \u003cli\u003e\n        \u003cstrong\u003eDirect ppO₂ measurement:\u003c\/strong\u003e\n        measures oxygen partial pressure from 0 to 2.0 bar\n      \u003c\/li\u003e\n      \u003cli\u003e\n        \u003cstrong\u003eHyperbaric chamber oxygen monitoring:\u003c\/strong\u003e\n        designed specifically for chamber atmospheres and other\n        pressurized environments\n      \u003c\/li\u003e\n      \u003cli\u003e\n        \u003cstrong\u003ePortable oxygen analyzer:\u003c\/strong\u003e\n        compact enough to hand carry or position within confined spaces\n      \u003c\/li\u003e\n      \u003cli\u003e\n        \u003cstrong\u003eLong battery life:\u003c\/strong\u003e\n        approximately 800 hours of continuous operation from a single\n        9V PP3 battery\n      \u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Key Features --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eKey Features\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n      \u003cdiv class=\"hc-feature-grid\"\u003e\n\n        \u003cdiv class=\"hc-feature-card hc-new-feature\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003eO₂\u003c\/span\u003e\n            \u003ch4\u003eHyperbaric Oxygen Partial Pressure Monitoring\u003c\/h4\u003e\n            \u003cspan class=\"new-badge\"\u003eppO₂\u003c\/span\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            A dedicated \u003cstrong\u003eoxygen partial pressure analyzer\u003c\/strong\u003e\n            designed for pressure-variable and hyperbaric environments.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eMeasurement range from 0 to 2.0 bar ppO₂\u003c\/li\u003e\n              \u003cli\u003eDirect partial pressure measurement\u003c\/li\u003e\n              \u003cli\u003eDesigned for hyperbaric chamber oxygen monitoring\u003c\/li\u003e\n              \u003cli\u003eSuitable as a portable ppO₂ analyzer\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card hc-new-feature\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e◎\u003c\/span\u003e\n            \u003ch4\u003ePressure-Rated Hyperbaric O₂ Analyzer\u003c\/h4\u003e\n            \u003cspan class=\"new-badge\"\u003eHYPERBARIC\u003c\/span\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            A true \u003cstrong\u003epressure-rated oxygen analyzer\u003c\/strong\u003e engineered\n            for operation across a wide range of ambient pressures.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eOperating pressure: 0.8 to 60 bar absolute\u003c\/li\u003e\n              \u003cli\u003eEquivalent manufacturer rating to approximately 600 MSW \/ 2000 FSW\u003c\/li\u003e\n              \u003cli\u003e1.5 ATA and 2.0 ATA fall well within the published operating range\u003c\/li\u003e\n              \u003cli\u003eDesigned specifically for hyperbaric environments\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e▣\u003c\/span\u003e\n            \u003ch4\u003eLarge LCD Display\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Simple digital display provides fast access to oxygen partial\n            pressure measurements.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eLarge numerical LCD readout\u003c\/li\u003e\n              \u003cli\u003eDisplays oxygen partial pressure directly\u003c\/li\u003e\n              \u003cli\u003eSimple single-switch operation\u003c\/li\u003e\n              \u003cli\u003eReading appears within approximately one to two seconds after startup\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e⚡\u003c\/span\u003e\n            \u003ch4\u003eApprox. 800-Hour Battery Life\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            A single replaceable 9V PP3 battery provides long-duration\n            portable operation.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eApproximately 800 hours continuous use\u003c\/li\u003e\n              \u003cli\u003eAbout one month of continuous operation\u003c\/li\u003e\n              \u003cli\u003eApproximately three months when used eight hours per day\u003c\/li\u003e\n              \u003cli\u003eLow-battery warning displayed on screen\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e◈\u003c\/span\u003e\n            \u003ch4\u003eTemperature-Compensated O₂ Sensor\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Electrochemical sensing technology is individually temperature\n            compensated across the rated operating range.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eAnalox electrochemical oxygen sensor\u003c\/li\u003e\n              \u003cli\u003eTemperature compensation integrated into sensor design\u003c\/li\u003e\n              \u003cli\u003eStable readings across changing environmental conditions\u003c\/li\u003e\n              \u003cli\u003eReplaceable sensor architecture\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e◆\u003c\/span\u003e\n            \u003ch4\u003eCompact Portable Oxygen Analyzer\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Designed for confined spaces where traditional instrumentation\n            may be impractical.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eApprox. 98 mm high\u003c\/li\u003e\n              \u003cli\u003eApprox. 64 mm wide\u003c\/li\u003e\n              \u003cli\u003eApprox. 36 mm deep\u003c\/li\u003e\n              \u003cli\u003eApprox. 200 g \/ 7 oz\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e↔\u003c\/span\u003e\n            \u003ch4\u003eLocal or Remote Sampling\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Monitor the atmosphere immediately around the analyzer or use\n            an optional sampling kit for remote measurements.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eLocal atmosphere measurement by sensor diffusion\u003c\/li\u003e\n              \u003cli\u003eOptional remote sample-draw system\u003c\/li\u003e\n              \u003cli\u003eHand-operated aspirator bulb\u003c\/li\u003e\n              \u003cli\u003e2-meter sample line supplied with applicable sampling kit\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e💧\u003c\/span\u003e\n            \u003ch4\u003eBuilt for Humid Hyperbaric Environments\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            Designed with chamber humidity and condensation in mind.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eSpecially coated circuit boards\u003c\/li\u003e\n              \u003cli\u003eProtection against humidity and condensation\u003c\/li\u003e\n              \u003cli\u003eHydrophobic membrane protects the oxygen sensor inlet\u003c\/li\u003e\n              \u003cli\u003eVertical positioning helps prevent water accumulation at the sensor inlet\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Why Partial Pressure Matters --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eWhy Measure Oxygen Partial Pressure?\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cp\u003e\n        Oxygen concentration expressed as a percentage and oxygen\n        \u003cstrong\u003epartial pressure\u003c\/strong\u003e are related, but they are not the\n        same measurement.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        In a hyperbaric environment, total atmospheric pressure increases\n        during compression. Even if the percentage of oxygen remains\n        unchanged, its partial pressure increases because total atmospheric\n        pressure has increased.\n      \u003c\/p\u003e\n\n      \u003cdiv class=\"hyp-equation\"\u003e\n        ppO₂ (bar) = Oxygen Percentage × Absolute Pressure (bar) ÷ 100\n      \u003c\/div\u003e\n\n      \u003cp\u003e\n        For example, an atmosphere containing approximately 20.9% oxygen\n        at 1.0 bar absolute produces a ppO₂ of approximately 0.21 bar.\n        The same approximately 20.9% oxygen atmosphere at 2.0 bar\n        absolute produces a ppO₂ of approximately 0.42 bar.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        Because the Analox HYP reports \u003cstrong\u003eppO₂ directly\u003c\/strong\u003e, this\n        \u003cstrong\u003ehyperbaric oxygen analyzer\u003c\/strong\u003e provides a measurement\n        particularly relevant to pressurized chamber environments.\n      \u003c\/p\u003e\n\n      \u003cdiv class=\"hyp-tech-note\"\u003e\n        \u003cstrong\u003eImportant:\u003c\/strong\u003e The HYP displays partial pressure of\n        oxygen, not oxygen percentage. If oxygen percentage is required,\n        the user must also know the absolute atmospheric pressure and\n        calculate the percentage accordingly.\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Hyperbaric Applications --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eHyperbaric Applications\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Designed for Pressure-Variable Environments\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eHyperbaric Chamber Oxygen Monitoring\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Independent partial-pressure oxygen monitoring within\n            applicable hyperbaric chamber atmospheres.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eHyperbaric oxygen monitor\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Portable oxygen monitoring for appropriate\n            pressure-controlled chamber environments.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eDiving bells\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Designed for direct ppO₂ measurement within commercial\n            diving and saturation environments.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eHyperbaric lifeboats\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Compact design is suitable for confined hyperbaric rescue\n            and evacuation environments.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSubmarines\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Partial-pressure oxygen monitoring where internal atmospheric\n            pressure may differ from surface pressure.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eRemote atmosphere sampling\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Optional sampling accessories allow gas samples to be drawn\n            from remote areas at the same pressure as the analyzer.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Compatibility --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eHyperbaric Pressure Compatibility\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cp\u003e\n        The Analox HYP has a manufacturer-specified operating-pressure\n        range of \u003cstrong\u003e0.8 to 60 bar absolute\u003c\/strong\u003e. This makes it a\n        true \u003cstrong\u003epressure-rated hyperbaric O₂ analyzer\u003c\/strong\u003e and places\n        the operating pressure of typical mild and moderate pressure\n        hyperbaric chambers comfortably within its published range.\n      \u003c\/p\u003e\n\n      \u003cdiv data-title=\"Pressure Reference\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003e1.3 ATA chamber\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. 1.32 bar absolute\u003cbr\u003e\n            \u003cstrong\u003eWithin HYP operating range\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003e1.5 ATA chamber\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. 1.52 bar absolute\u003cbr\u003e\n            \u003cstrong\u003eWithin HYP operating range\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003e2.0 ATA chamber\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. 2.03 bar absolute\u003cbr\u003e\n            \u003cstrong\u003eWithin HYP operating range\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eHYP maximum rating\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e60 bar absolute\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"hyp-tech-note\"\u003e\n        \u003cstrong\u003ePressure-change limitation:\u003c\/strong\u003e\n        The manufacturer specifies a compression\/decompression rate of\n        less than \u003cstrong\u003e2 bar per minute\u003c\/strong\u003e. The analyzer should\n        not be passed through a medical lock or other pressure-transfer\n        system that subjects it to rapid pressure changes.\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Technical Specifications --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Analox HYP Hyperbaric Oxygen Analyzer Specifications\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eProduct\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analox HYP Hyperbaric Portable Oxygen Analyzer\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eAnalyzer type\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Portable hyperbaric oxygen partial pressure analyzer\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMeasurement\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Oxygen partial pressure (ppO₂)\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMeasurement range\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e0 to 2.0 bar ppO₂\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor type\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analox 9100-9212-5H electrochemical oxygen sensor\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eAccuracy\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            ±1% of reading plus ±1 LSD\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eTemperature effect\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            ±0.2% of reading per °C\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eLong-term drift\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Typically approximately 5% of reading per year\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eOperating temperature\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e0°C to 40°C\u003c\/strong\u003e\u003cbr\u003e\n            Approx. 32°F to 104°F\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eOperating pressure\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e0.8 to 60 bar absolute\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eDepth equivalent\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. 600 MSW \/ 2000 FSW manufacturer rating\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCompression \/ decompression rate\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e\u0026lt;2 bar per minute\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eDisplay\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Large digital LCD\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            9V PP3\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eContinuous battery life\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. \u003cstrong\u003e800 hours\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eIntermittent battery life\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. 3 months at 8 hours per day\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eDimensions\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            64 × 98 × 36 mm\u003cbr\u003e\n            Approx. 2.52 × 3.86 × 1.42 in.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eWeight\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. 0.200 kg \/ 200 g \/ 7.1 oz\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Sensor --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eOxygen Sensor\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Analox Electrochemical O₂ Sensor\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor model\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            9100-9212-5H\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor technology\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Electrochemical oxygen cell\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eMaximum expected life\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Up to approximately 3 years in normal air at standard\n            atmospheric pressure\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eTypical replacement planning\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Manufacturer documentation references replacement at\n            approximately 12, 18, or 24 months depending on application\n            and exposure\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eHigh O₂ exposure\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Higher oxygen partial pressures consume the electrochemical\n            sensor more quickly and may reduce service life\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eTemperature compensation\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Sensor incorporates temperature-compensation components\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Operation --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eOperation \u0026amp; Monitoring\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Simple Portable Hyperbaric Monitoring\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eStartup\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Switch the analyzer on and the oxygen measurement appears\n            on the LCD within approximately one to two seconds\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eLocal monitoring\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Ambient gas diffuses directly into the oxygen sensor for\n            measurement of the local chamber atmosphere\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eRemote monitoring\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Optional sample-draw kit allows a remote atmosphere at the\n            same pressure to be sampled\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eLow battery indication\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Battery symbol appears when battery voltage approaches\n            depletion\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"hyp-tech-note\"\u003e\n        Avoid exhaling directly over the oxygen sensor while taking a\n        measurement. Exhaled air has a lower oxygen concentration than\n        the surrounding atmosphere and can temporarily alter the reading.\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Calibration --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eCalibration\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cp\u003e\n        Periodic calibration is required because electrochemical oxygen\n        sensors gradually change output as the sensor is consumed over\n        its operating life.\n      \u003c\/p\u003e\n\n      \u003cdiv data-title=\"Calibration Options\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eFresh-air calibration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            May be used where the analyzer will primarily measure\n            air-equivalent atmospheres. Atmospheric pressure, temperature,\n            and humidity should be considered.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003ePure oxygen calibration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Manufacturer documentation identifies pure oxygen calibration\n            as the preferred method where measurements will span the\n            sensor's full range.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCalibration gas\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Known calibration gas may be applied using the appropriate\n            Analox flow adapter and regulator.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eReference analyzer\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Calibration may also be checked against an appropriate\n            reference analyzer when both instruments are exposed to\n            the same gas.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCalibration adjustment\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Recessed front-panel potentiometer provides manual\n            calibration adjustment\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eTypical interval\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Calibration frequency depends on accuracy requirements and\n            application. Manufacturer documentation discusses six-month\n            calibration as appropriate for many users, with more frequent\n            checks in critical applications.\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Humidity --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eHumidity \u0026amp; Condensation\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cp\u003e\n        Hyperbaric environments can have elevated humidity and condensation.\n        The HYP is designed with these conditions in mind.\n      \u003c\/p\u003e\n\n      \u003cdiv data-title=\"Environmental Design\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCircuit protection\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Circuit boards are specially coated to help protect against\n            humidity and condensation\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor membrane\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Hydrophobic membrane helps prevent liquid water from entering\n            the oxygen sensor\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCondensation management\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analyzer should be positioned so condensed water cannot\n            accumulate over the sensor inlet\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eRecommended orientation\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Vertical positioning helps allow collected moisture to drain\n            away from the sensor inlet\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Battery --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eBattery \u0026amp; Hyperbaric Operation\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Portable Power System\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Single 9V PP3 battery\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eContinuous runtime\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Approx. 800 hours\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eLow battery warning\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Display provides low-battery indication before battery\n            exhaustion\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eHyperbarically tested battery\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analox documentation identifies a hyperbarically tested PP3\n            battery for higher-pressure applications\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"hyp-tech-note\"\u003e\n        Analox recommends considering a battery tested for hyperbaric\n        operation when the analyzer is used above 1.5 bar absolute,\n        particularly in critical applications.\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Accessories --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eAccessories \u0026amp; Replacement Parts\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Manufacturer-Listed Accessories\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eReplacement O₂ sensor\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analox 9100-9212-5H\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eHyperbarically tested battery\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analox 2557-1855 PP3 battery\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSample draw kit\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            GENPISDK sample draw kit with flow adapter, aspirator bulb,\n            2 m neoprene tubing, and stainless steel probe\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCalibration kit\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            SA7 100HYP CALKIT manufacturer-listed calibration system\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eFlow adapter\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Analox 8000-0011GA flow adapter\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Maintenance --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eMaintenance\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Routine Maintenance\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eCalibration\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Periodically verify and calibrate the analyzer according to\n            the accuracy requirements of the application\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor inspection\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Inspect the electrochemical oxygen sensor for damage or\n            electrolyte leakage\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eBattery replacement\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Replace the 9V PP3 battery when the low-battery indicator\n            appears\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSensor replacement\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            Replace according to sensor condition, calibration performance,\n            oxygen exposure, and manufacturer guidance\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Warranty --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eWarranty\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv data-title=\"Manufacturer Warranty\" class=\"hc-spec-grid\"\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eElectronics\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e1 year\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eOxygen sensor\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            \u003cstrong\u003e3 months\u003c\/strong\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hc-spec-card\"\u003e\n          \u003cdiv class=\"hc-spec-label\"\u003eSupport\u003c\/div\u003e\n          \u003cdiv class=\"hc-spec-value\"\u003e\n            MedEq Fitness provides product guidance and coordinates\n            applicable manufacturer support\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Safety --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eImportant Safety \u0026amp; Use Information\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv class=\"hyp-tech-note\"\u003e\n        \u003cstrong\u003ePressure-change limitation:\u003c\/strong\u003e\n        Do not subject the HYP analyzer to rapid compression or\n        decompression. The manufacturer's specified maximum rate is\n        less than 2 bar per minute. Do not transfer the analyzer through\n        a medical lock or other system where pressure may change more\n        rapidly.\n      \u003c\/div\u003e\n\n      \u003cp\u003e\n        The oxygen sensor is an electrochemical device containing a\n        potassium hydroxide electrolyte. Damaged or leaking sensors\n        should not be handled as normal components and must be managed\n        according to manufacturer safety instructions.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        This product is a hyperbaric atmospheric monitoring instrument.\n        Users are responsible for establishing appropriate monitoring\n        protocols, alarm thresholds, calibration intervals, and operating\n        procedures for their specific hyperbaric installation.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\n  \u003c!-- Why MedEq --\u003e\n  \u003cdiv class=\"hc-accordion-item\"\u003e\n    \u003ch3 class=\"hc-accordion-header\"\u003eWhy Buy Through MedEq Fitness?\u003c\/h3\u003e\n\n    \u003cdiv class=\"hc-accordion-content\"\u003e\n\n      \u003cdiv class=\"hc-feature-grid\"\u003e\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e◎\u003c\/span\u003e\n            \u003ch4\u003eHyperbaric Equipment Expertise\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            MedEq understands the interaction between chamber pressure,\n            oxygen delivery, ventilation, and atmospheric monitoring.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eHyperbaric-specific product selection\u003c\/li\u003e\n              \u003cli\u003ePressure-rating review\u003c\/li\u003e\n              \u003cli\u003eChamber accessory guidance\u003c\/li\u003e\n              \u003cli\u003eProfessional and residential equipment support\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n\n        \u003cdiv class=\"hc-feature-card\"\u003e\n          \u003cdiv class=\"feature-header\"\u003e\n            \u003cspan class=\"feature-icon\"\u003e✓\u003c\/span\u003e\n            \u003ch4\u003eApplication-Focused Support\u003c\/h4\u003e\n          \u003c\/div\u003e\n\n          \u003cp class=\"feature-summary\"\u003e\n            We can help determine whether the HYP, Sub Aspida, or another\n            monitoring platform is appropriate for the intended application.\n          \u003c\/p\u003e\n\n          \u003cdiv class=\"feature-details\"\u003e\n            \u003cul\u003e\n              \u003cli\u003eHyperbaric oxygen analyzer selection\u003c\/li\u003e\n              \u003cli\u003eO₂ monitoring requirements\u003c\/li\u003e\n              \u003cli\u003eCO₂ monitoring considerations\u003c\/li\u003e\n              \u003cli\u003eOperating-pressure compatibility\u003c\/li\u003e\n              \u003cli\u003ePortable versus continuous monitoring options\u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/div\u003e\n\n          \u003cbutton class=\"hc-feature-more-toggle\" type=\"button\"\u003e\n            More details ▾\n          \u003c\/button\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003cp style=\"margin-top:18px;\"\u003e\n        \u003cstrong\u003e\n          MedEq Fitness - Physician-founded, veteran-owned,\n          physician-guided wellness and recovery equipment.\n        \u003c\/strong\u003e\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"MedEq Fitness","offers":[{"title":"Default Title","offer_id":56961379401894,"sku":"HC-HYPO2","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0682\/5512\/1574\/files\/HYP-1.jpg?v=1786758111","url":"https:\/\/medeqfitness.com\/products\/analox-hyp-hyperbaric-o2-analyzer","provider":"MedEq Fitness","version":"1.0","type":"link"}